The user can determine output functionality (momentary or maintained action) and program the system to respond as desired. This is determined by the following procedure:
1. Turn the receiver off. Turn the transmitter on (press and hold POWER until both LEDs turn on, then release)
2. Press and hold 1, 4, and 6 and release. Red LED should be blinking on the transmitter
3. Turn the receiver on, make sure the green LED is blinking on the receiver before proceeding to the next step. Be sure all outputs are connected to a load and that there are no error codes present (NOTE: outputs may cycle on and off while programming)
4. Are any outputs to be latched (push on/push off)? If yes continue. If no, skip to step 9 for outputs to be momentary.
5. Press button 1-6 corresponding to output 1-6 that is to be latched, until green LED goes on, then off
6. Press button that corresponds to OFF until green LED goes on, then off. This can be the same button that turns the output on. In this case, pressing the button alternates the output between ON and OFF.
7. If latched output should turn OFF for transmitter out of range condition press the button defined in step 6. If latched output should stay ON for transmitter out of range condition press any button other than button defined in step 6.
8. Repeat steps 5, 6, and 7 for any more outputs that are to be latched
9. Press POWER briefly. The receiver's red LED should blink, indicating that this step is accepted and complete. The red LED on the transmitter should also start to blink a different rate.
10. Are any outputs to be disabled (no output and no error code)? If yes, continue, if no, skip to step 12
11. One at a time, press and hold each button 1-8 corresponding to output 1-8 that is to be disabled, until the green LED goes on, then off
12. Press POWER briefly. The receiver's red LED should blink, indicating that this step is accepted and complete. The red LED on the transmitter should also start to blink at a different rate.
13. Is it desired to use the pump functionality (see description below)? If yes, continue, if no, skip to step 15
14. One at a time, press and hold each button 1-6 corresponding to output 1-6 that is to be associated with the pump output, until the green LED goes on, then off
15. Press POWER briefly. The receiver's red LED should blink, indicating that this step is accepted and complete. The red LED on the transmitter should also start to blink at a different rate.
16. Is it desired to use the e-stop functionality (see description below)? If yes, continue, if no, skip to step 18
17. To engage the e-stop functionality, press button 2 until the green LED goes on, then off
18. If no error code is desired for the E-STOP output press button 3 to disable otherwise go to step 19 to keep error code enabled
19. If the E-STOP output should turn OFF for transmitter out of range condition press button 4 otherwise go to step 20 to keep the output ON for transmitter out of range condition
20. If no error code is desired for the PUMP output press button 1 to disable otherwise go to step 21 to keep error code enabled
21. Press POWER briefly. The receiver's red LED should blink, indicating that this step is accepted and complete.
22. One at a time, press and hold each button 1-6 that the corresponding output error code needs to be disabled, until the green LED goes on, then off
23. Press POWER briefly. The receiver's red LED should blink, indicating that this step is accepted and complete.
24. Programming complete
NOTES:
· Pump functionality: output 9 will turn on with any outputs that have been associated with it
· E-stop functionality: output 10 will be on as long as the transmitter is on. If the transmitter is turned off or POWER is pressed output 10 will go off along with all latched outputs. To reset, turn the transmitter back on or re-cycle power to the receiver and re-engage the outputs as before
· If the receiver does not blink the red LED after each sequence or the transmitter's red LED does not blink at a different rate as described above, the programming was not accepted for that section. Start from the beginning and go slowly. Keep a distance of 2-3 feet from the receiver when programming.
· The factory settings are: 8 momentary outputs, no pump output, and no e-stop output
0 Comments