Hydraulic Cooling Fan Service Bulletin 8/14/2024


DATE: 8/14/2024
SUBJ: Electric Distributor Maximizer

 

Machine Model: MAX2B1900P / MAX3B1900F

 

Serial Numbers:
MAX2-354451

MAX2-382825

MAX2-403304

MAX2-414632
MAX2-430441
MAX2-431315

MAX3-443308

MAX2-447392

MAX2-449876

 

Action Requested: Immediate Inspection and Correction

 

Please notify customers with a recommendation to check and verify if the cooling fan on the distributor tank is running with the PTO switch on. If the fan is running, no action is required. If the fan is not running, advise they turn the master switch located on the control box to on and the fan should start running. If the fan starts to run, please instruct the operator to have the master switch on any time the PTO is on for the hydraulic cooling fan to operate properly.

 

Parts Required: None at this time.

 

Issue Description:

Leeboy has discovered that there are some of distributor trucks wired to the control box instead of the PTO switch. LeeBoy is working to resolve this matter and plans to visit each distributor and inspect/update at a later time.

 

Action Detail:
Check operation of the hydraulic cooling fan wiring and instruct the operator on how to operate.

 

For questions or concerns please call Rapid Response at 844-205-5499 or email support@leeboy.zendesk.com